5 SKUs passed this rule group.
5 checks / 0 issuesScenario Details
Maximum Utilization
V275 to V119 / TRUCK 1
Truck Utilization99.53%
Priority Compliance15.12%
Decision Score65.86
Constraint Compliance100%
Loaded SKUs5
Pending SKUs7
Volume and Score
7,89,61,642 cm3 loaded
3,70,836 cm3 unused from 7,93,32,477 cm3 truck capacity.
Why this scenario?
Uses truck volume better than the other available scenarios.
No configured loading constraint violations were found.
Focuses on filling the truck as much as possible.
Trade-offs to review
- Can sacrifice some priority protection compared with priority-led scenarios.
Optimization Story
What this plan means
- LoadWise reviewed 11 candidate SKUs for V275 to V119 using TRUCK 1.
- Maximum Utilization is recommended because it achieved 99.53% truck utilization and 15.12% priority compliance.
- The plan loads 5 SKUs and 118 units, leaving 7 SKUs and 531 units pending.
- Configured loading, compatibility, orientation, and heavy-on-light checks did not show violations.
- 2 high-priority SKUs still have pending quantity and should be reviewed first.
- Refrigerator products consumed the largest share of loaded volume.
- This recommendation explains what to load and why; physical placement and loading sequence are not generated in this stage.
Constraint Impact Summary
Rule groups that affected loaded or pending products in this scenario.
No active checks recorded for this scenario.
0 checks / 0 issues1 SKU passed this rule group.
2 checks / 0 issues0 SKUs passed this rule group.
1 checks / 0 issuesNo active checks recorded for this scenario.
0 checks / 0 issuesScenario Review
- LoadWise reviewed 11 candidate SKUs for V275 to V119 using TRUCK 1.
- Maximum Utilization is recommended because it achieved 99.53% truck utilization and 15.12% priority compliance.
- The plan loads 5 SKUs and 118 units, leaving 7 SKUs and 531 units pending.
- Configured loading, compatibility, orientation, and heavy-on-light checks did not show violations.
- 2 high-priority SKUs still have pending quantity and should be reviewed first.
- Refrigerator products consumed the largest share of loaded volume.
- This recommendation explains what to load and why; physical placement and loading sequence are not generated in this stage.
Maximum Utilization selected products to maximize truck utilization while obeying active loading, compatibility, orientation, and system rules. It loaded 5 SKUs and left 7 SKUs pending. Loaded volume is 78961642 cm3 out of 79332477 cm3. Main pending drivers: 6 SKUs: truck volume capacity was exhausted. 1 SKU: category is missing. No truck placement, loading sequence, 2D layout, or 3D layout is generated in Stage 4.